Circuit Diagram Errors. ----------------------- (from Terry Froggatt) On circuit diagram A19, for FTM read MTF, on input 4 to LSA D. On circuit diagram A24, two inhibit driver diodes are drawn the wrong way round, I think D12 & D13 are wrong, and D10 & D11 are right. On circuit diagram C26, in the blue ringbinders, where it is at issue 3, the CVT chassis is shown as connected to mains neutral, whereas in reality I assume it is connected to mains earth. The same error occurs in the grey ringbinders 4.1.3 & 4.1.4, figure 3 issue 3, whilst the connection is absent at issue 2. On circuit diagram B10 sheet 2, pin 13 for BD POS 53 is shown as connected to 53/AE (on the same board) which probably should be 57/AE, pin 10 is called RGS but probably should be RGS-bar. On circuit diagram 32, in 32 is shown connected to +6v whereas in reality it is connected to 0v.